Swabbing of Wells


Very often an operation on dropping the level of fluid in a well is integrated with hydrodynamic researches. Prior to swabbing an autonomous manometer installed on an uncoupling device or on a suspension is lowered into a well with the aim to register the dynamics of fluid level dropping in a swabbing well.

In the process of staying on a fluid level build-up curve (FLBC) it may be regulated with geophysical instruments or a sonic depth finder.

1 - tubing; 2 - packer; 3 - geophysical cable; 4 - well device on a cable; 5 - packer modulus; 6 - well device on a cable; 7 - logger lift.

The alternative scheme of a job - a tester plus swab - is an effective method of carrying out qualified researches. In a set with testing equipment and a packer, the manometers and deep sampling devices, if needed, are lowered into a well. Then a multiple process of fluid level dropping up to the given depression values by swabbing is performed. At that the inflow comes only into a tubing space which considerably reduces time on dropping the level of fluid in a well. With a help of testing facilities as well as with a geophysical packer-anchor which cuts the inner tubing space (See pic.), there is an opportunity of registering the FLBC with the aim of receiving detailed information on filtration and capacity properties of an object under study and also on the state of a critical area of a well.